乳业科学与技术 ›› 2023, Vol. 46 ›› Issue (3): 27-31.DOI: 10.7506/rykxyjs1671-5187-20230228-012

• 分析检测 • 上一篇    

蔗糖脂肪酸酯中残留溶剂的测定

符昌雨, 杨 丹, 程志翔   

  1. 上海市质量监督检验技术研究院,国家市场监管重点实验室(乳及乳制品检测与监控技术),上海 200233
  • 发布日期:2023-09-18

Determination of Residual Solvents in Sucrose Fatty Acid Esters

FU Changyu, YANG Dan, CHENG Zhixiang   

  1. Key Laboratory of Milk and Dairy Products Detection and Monitoring Technology for State Market Regulation, Shanghai Institute of Quality Inspection and Technical Research, Shanghai 200233, China
  • Online:2023-09-18

摘要: 建立顶空气相色谱法测定蔗糖脂肪酸酯中的甲醇、异丙醇、甲基乙基酮、乙酸乙酯和异丁醇5 种残留溶剂。称取样品直接顶空进样,建立以DB-1毛细管柱(60 m×530 μm,1 μm)为分析柱、平衡温度80 ℃、平衡时间40 min的残留溶剂测定方法。结果表明:5 种残留溶剂在0.05~10.00 μg范围内线性关系良好,相关系数均大于0.999;甲醇、异丙醇、甲基乙基酮、乙酸乙酯和异丁醇的方法定量限依次为0.024 4、0.019 7、0.022 7、0.024 5、0.019 2 mg/kg,平均回收率为81.7%~96.8%,相对标准偏差为1.90%~4.52%;方法前处理操作简单快速、回收率和精密度良好,适用于蔗糖脂肪酸酯中5 种残留溶剂检测;20 批次蔗糖脂肪酸酯样品检测结果显示,17 批次样品中检出的3 种溶剂残留量均符合世界卫生组织食品添加剂联合专家委员会的要求,甲醇的检出率最高达到80%,亲油型样品中残留溶剂检出种类主要为甲醇,其残留量最高达到9.42 mg/kg,亲水型样品中残留溶剂检出种类较亲油型多,但含量相对较低。

关键词: 蔗糖脂肪酸酯;顶空气相色谱;残留溶剂;直接进样

Abstract: A headspace gas chromatography (HSGC) method was established for the determination of residual methanol, isopropanol, methyl ethyl ketone, ethyl acetate and isobutanol in sucrose fatty acid esters. Samples were directly injected into the headspace. The chromatographic analysis was performed on a DB-1 column (60 m × 530 μm, 1 μm) equilibrated for 40 min at 80 ℃. The results showed that the calibration curves for the five solvents were linear in the range of 0.05–10.00 μg, with correlation coefficients greater than 0.999, and the limits of quantitation (LOQ) for methanol, isopropanol, methyl ethyl ketone, ethyl acetate and isobutanol were 0.024 4, 0.019 7, 0.022 7, 0.024 5 and 0.019 2 mg/kg, respectively. The average recoveries for all analytes were in the range from 81.7% to 96.8%, and the relative standard deviation (RSD) for precision ranged from 1.90% to 4.52%. The pretreatment method was simple and rapid, with good recovery and precision, and was suitable for the analysis of the five residual solvents in sucrose fatty acid esters. A total 20 lots of of sucrose fatty acid ester samples were detected by the proposed method. The residues of three solvents in 17 of them met the requirements of the Joint FAO/WHO Expert Committee on Food Additives (JECFA). The detection rate of methanol was highest (80%), and methanol was the major solvent retained in the lipophilic samples at a level up to 9.42 mg/kg. More solvents were detected in the hydrophilic samples at lower levels.

Key words: sucrose fatty acid esters; headspace gas chromatography; residual solvents; direct injection

中图分类号: