[an error occurred while processing this directive]

Journal of Dairy Science and Technology ›› 2016, Vol. 39 ›› Issue (2): 17-20.DOI: 10.15922/j.cnki.jdst.2016.02.005

• Analysis & Detection • Previous Articles     Next Articles

Simultaneous Determination of 2 Ultraviolet Absorbers and 2 Antioxidants in Milk by High Performance Liquid Chromatography

ZHANG Dayuan, LI Hui, ZHANG Lantian, AI Lianfeng   

  1. (1.Hebei Key Laboratory of Food Safety, Hebei Food Inspection and Research Institute, Shijiazhuang 050091, China; 2.Hebei Hengshui High School, Hengshui 053000, China; 3.Hebei Entry-Exit Inspection and Quarantine Technical Center, Hebei Entry-Exit Inspection and Quarantine Bureau, Shijiazhuang 050051, China)
  • Online:2016-03-01 Published:2022-02-07

高效液相色谱法同时测定液态乳中的2种紫外吸收剂和2种抗氧化剂

张大原, 李挥, 张兰天, 艾连峰   

  1. 河北省食品检验研究院,河北省食品安全重点实验室,河北石家庄 050091;河北衡水中学,河北衡水 053000;河北省食品检验研究院,河北省食品安全重点实验室,河北石家庄 050091;河北出入境检验检疫局,检验检疫技术中心,河北石家庄 050051
  • 基金资助:
    河北省科技计划项目(15275505D)

Abstract: A method was developed for the simultaneous determination of 2 ultraviolet absorbers UV-326, UV-1577 and 2 antioxidants AO-1010 and AO-2246 in milk by high performance liquid chromatography. Samples were extracted with acetonitrile. The effective separation of the target analytes was accomplished on Agilent HC-C8 (150 mm × 4.6 mm, 5.0 μm) column with gradient elution procedure using a mixture of water and acetonitrile as the mobile phase. External calibration was used for quantitative determination at detection wavelength of 280 nm. The linearity of 4 analytes were satisfactory with a correlation coefficient of > 0.9995 at concentrations ranging from 0.05 to 50 μg/mL. The limits of detection of the method were 0.02?0.5 mg/kg, and the recoveries at different spiked levels and precision (RSD) were 69.08%?115.87% and 0.43%?9.94%, respectively. The method is simple, sensitive, reproducible and suitable for the simultaneous determination of 2 ultraviolet absorbers and 2 antioxidants in milk.

Key words: high performance liquid chromatography (HPLC); ultraviolet absorber; antioxidants; milk

摘要: 建立液态乳中2种紫外吸收剂(UV-326和UV-1577)和2种抗氧化剂(AO-1010、AO-2246)的高效液相色谱测定方法.前处理采用乙腈提取液态乳中目标化合物,样品用正己烷提取;检测经Agilent HC-C8反相色谱柱,以乙腈-水作为流动相,梯度洗脱程序进行分离,280 nm波长下检测.结果表明:分析物在0.05~50 μg/mL质量浓度范围内线性关系良好,线性相关系数>0.999 5,方法检出限为0.02~0.5 mg/kg.方法在3个水平的加标回收率为69.08%~115.87%,相对标准偏差为0.43%~9.94%.该方法操作简单、灵敏度高、重现性好,适用于液态乳中紫外吸收剂和抗氧化剂的同时测定.

关键词: 高效液相色谱;紫外吸收剂;抗氧化剂;液态乳